Query (Map Service/Layer)
- URL:https:// <layer-url>/query
- Required Capability:Data
- Version Introduced:9.3
Description

Prior to 10.0, the query operation could only be performed on layers. From 10.0 onward, the query operation can be performed on tables and layers. Querying annotation is supported at the layer level, however querying annotation at the sublayer level is not supported.
Note that all parameters related to geometry will be ignored when querying tables.
The result of this operation is a feature set. This feature set contains feature objects including the values for the fields requested by the user. For layers, if you request geometry information, the geometry of each feature is also returned in the feature set. For tables, the feature set does not include geometries.
New in 10.9
- The Query operation is enhanced to return spatially aggregated results in regularly shaped polygon (such as hexagon, square, and so on) tessellation from point features.
Note:
The layer must be enabled with feature binning capability.
- You need to check the value for SupportsLOD property in the layer resources before making requests with lod, lodType or lodSR optionally combined with outStatistics and other query parameters.
- Percentile in an outStatistics query is supported for layers and tables in a file geodatabase.
10.8.1
The layer query operation supports percentile as a statisticType when using outStatistics for map services published from ArcGIS Pro that reference enterprise geodatabase data. Layers that support percentiles include the supportsPercentileStatistics property as true, found in the advancedQueryCapabilities layer object.
New in 10.7.1
- Map Services now support the protocol buffer (pbf) format. This format is supported on map services from ArcGIS Pro. The supportedQueryFormats layer property will list pbf if it is available on the layer.
New in 10.7
- Support for amf output format was removed.
New in 10.6.1
- Supports the following new parameters.
- historicMoment to query from a given moment in an archive enabled layer.
- Supports returning 'number of unique values', instead of a list of unique value, off a field when values for both returnCountOnly and returnDistinctValues are true.
- Map services now support quantizationParameters.
New in 10.5
- Supports the following new parameters.
- datumTransformations to provide a desired datum transformation to be applied while features get projected.
- rangeValues to set values to ranges.
- parameterValues to set value to parameterized filters.
- Supports passing in SQL expressions in outStatistics. Check supportsSqlExpression on resources to find out whether the layer/table allows SQL expressions.
New at 10.4
- Supports GeoJSON as a response format.
- Supports passing in expressions in orderByFields and groupByFieldsForStatistics. When useStandardizedQueries is true, you can pass in expressions that conform to StandardizedQueries specifications. Otherwise, any expressions that are supported by the underlying database can be passed in.
New at 10.3.1
- The exceededTransferLimit property is now included in the JSON response when paging through a query result with the resultOffset and resultRecordCount parameters. When exceededTransferLimit is true, it indicates there are more query results and you can continue to page through the results. When exceededTransferLimit is false, it indicates that you have reached the end of the query results.

When not using the resultOffset and resultRecordCount parameters, the exceededTransferLimit property may also be included in the query results. In this case, the property will be true only if the number of records exceeds the maximum number configured by the server administrator.

In some cases when using the resultOffset and resultRecordCount parameters, the exceededTransferLimit property may be included in the query results even though the value specified in the resultRecordCount has not been exceeded. This is due to internal spatial index filtering of the query results. For this reason you should always rely on the exceededTransferLimit property to determine if you should page through results rather than relying on the number of results returned from each page. In some extreme cases zero results can be returned but the exceededTransferLimit property will be returned. In these cases you should continue paging though your results until exceededTransferLimit is no longer returned.
New at 10.3
- Supports pagination in a query layer. UseresultOffset and resultRecordCount parameters to page through a query result.
- Note that when you pass in one of these two parameters and orderByFields is left empty, the map service uses the object-id field to sort the result. For a query layer with a pseudocolumn as the object-id field (for example, FID), you must provide orderByFields or else the query will fail.
- query now supports true curves in an input geometry parameter.
- query now returns true curves in output geometries when the returnTrueCurves parameter is set to true.
- Learn more about JSON Curve Objects in Geometry Objects.
New at 10.2
- The where parameter value must conform to the standardized queries, if the layer/table resource advertises useStandardizedQueries is true. Learn more about standardized queries.
- outStatistics now supports the gdbVersion parameter.
New at 10.1 SP1
- Support for a new parameter named returnDistinctValues that accepts a Boolean value was added. When true, the query result would contain distinct values based on the fields specified in the outFields parameter.
- outStatistics now supports the geometry parameter.
New at 10.1
- Support for orderByFields, outStatistics, and groupByFieldsForStatistics was added for both layers and tables.
- Support for returnZ and returnM was added for layers. Default value for returnZ and returnM is false.
- When output format f is kmz, the result would always contain a z-value irrespective of the returnZ property value. If the feature geometry does not support z, a default value of 0 would be returned for z.
- Support for the gdbVersion parameter was added. Use this parameter to specify the geodatabase version to query.
- The geometryPrecision parameter was introduced. This option can be used to specify the number of decimal places in the response geometries returned by the query operation.
- JSON response contains an optional property exceededTransferLimit. This property will be true only if the number of records exceeds the maximum number configured by the server administrator.
New at 10.0 SP1
- At 10.0 SP1, support for returning the count (number of features/records) that would be returned by a query was added for both layers and tables.
New at 10.0
- Support for querying layers and tables based on time was added at 10.0. For time-aware layers, users can use the time parameter to specify the time instant or the time extent to query.
- A new returnIdsOnly parameter was introduced. If set to false (default), the response will be a feature set. If true, the response will be an array of object IDs.
- Note that while there is a limit on the number of features included in the feature set response, there is no limit on the number of object IDs returned in the ID array response. Clients can exploit this to get all the query conforming object IDs by specifying returnIdsOnly=true and subsequently requesting feature sets for subsets of object IDs.
- Support for query based on objectIds was added.
- Support for f=amf was added.
- Support for generalizing geometries returned by the query operation was added.
- The
query operation returns an additional fields array (JSON and AMF only) that contains array of field information for returned values. This array contains only fields specified in the outFields parameter. See Layer/Table for details on fields.
Note:
The domains member is not included in field information objects returned with the response.
- The fieldAliases member is deprecated.
You can provide arguments to the query operation as query parameters defined in the parameters table below.
Request parameters
Parameter |
Details |
---|---|
text |
A literal search text. If the layer has a display field associated with it, the server searches for this text in this field. This parameter is shorthand for a WHERE clause of where <displayField> like '%<text>%'. The text is case sensitive. This parameter is ignored if the WHERE parameter is specified. Example
|
geometry |
The geometry to apply as the spatial filter. The structure of the geometry is the same as the structure of the JSON geometry objects returned by the ArcGIS REST API. In addition to the JSON structures, for envelopes and points, you can specify the geometry with a simpler comma-separated syntax. Syntax
|
geometryType |
The type of geometry specified by the geometry parameter. The geometry type can be an envelope, point, line, or polygon. The default geometry type is an envelope. Values: esriGeometryPoint | esriGeometryMultipoint | esriGeometryPolyline | esriGeometryPolygon | esriGeometryEnvelope |
inSR |
The spatial reference of the input geometry. The spatial reference can be specified as either a well-known ID or as a spatial reference JSON object. If the inSR is not specified, the geometry is assumed to be in the spatial reference of the map. |
spatialRel |
The spatial relationship to be applied on the input geometry while performing the query. The supported spatial relationships include intersects, contains, envelope intersects, within, and so on. The default spatial relationship is intersects (esriSpatialRelIntersects). Values: esriSpatialRelIntersects | esriSpatialRelContains | esriSpatialRelCrosses | esriSpatialRelEnvelopeIntersects | esriSpatialRelIndexIntersects | esriSpatialRelOverlaps | esriSpatialRelTouches | esriSpatialRelWithin | esriSpatialRelRelation |
relationParam |
The spatial relate function that can be applied while performing the query operation. An example for this spatial relate function is "FFFTTT***." For more information on this spatial relate function, refer to the documentation for the spatial relate function. |
where |
A WHERE clause for the query filter. Any legal SQL WHERE clause operating on the fields in the layer is allowed. Example
|
objectIds |
The object IDs of this layer or table to be queried. ![]() There might be a drop in performance if the layer/table data source resides in an enterprise geodatabase and more than 1,000 objectIds are specified. Syntax
|
time |
The time instant or the time extent to query. A null value specified for start time or end time will represent infinity for start or end time, respectively. Syntax
Syntax
|
distance | This parameter only applies if supportsQueryWithDistance is true. The buffer distance for the input geometries. The distance unit is specified by units. For example, if the distance is 100, the query geometry is a point, units is set to esriSRUnit_Meter, and all points within 100 meters of the point are returned. The geodesic buffer is created based on the datum of the output spatial reference if it exists. If there is no output spatial reference, the input geometry spatial reference is used. Otherwise, the native layer spatial reference is used to generate the geometry buffer used in the query. Syntax
Example
|
units | This parameter only applies if supportsQueryWithDistance is true. The unit for calculating the buffer distance. Values: esriSRUnit_Meter | esriSRUnit_StatuteMile | esriSRUnit_Foot | esriSRUnit_Kilometer | esriSRUnit_NauticalMile | esriSRUnit_USNauticalMile |
outFields |
The list of fields to be included in the returned result set. This list is a comma-delimited list of field names. If you specify the shape field in the list of return fields, it is ignored. To request geometry, set returnGeometry to true. You can also specify the wildcard "*" as the value of this parameter. In this case, the query results include all the field values. Example
|
returnGeometry |
If true, the result set includes the geometry associated with each result. The default is true. ![]() This parameter cannot be used with returnDistinctValues. Values: true | false |
maxAllowableOffset |
This option was added at 10.0. This option can be used to specify the maxAllowableOffset to be used for generalizing geometries returned by the query operation. The maxAllowableOffset is in the units of the outSR. If outSR is not specified, maxAllowableOffset is assumed to be in the unit of the spatial reference of the map. Example
|
geometryPrecision |
This option was added at 10.1. This option can be used to specify the number of decimal places in the response geometries returned by the query operation. This applies to x- and y-values only (not m- or z-values). Example
|
outSR |
The spatial reference of the returned geometry. The spatial reference can be specified as either a well-known ID or as a spatial reference JSON object. If outSR is not specified, the geometry is returned in the spatial reference of the map. When using outSR with pbf, the pbf format will use coordinate quantization for layer queries. When an output spatial reference is not provided for a query operation, the Map Service derives coordinate quantization parameters from the layer's spatial reference. If the precision in the layer's spatial references is inadequate for the client application's use, it should pass in a spatial reference with suitable precision as the output spatial reference. If the layer's source spatial reference has the desired precision and it is suitable for the client's use, the client can use the source layer's spatial reference as the output spatial reference. |
returnIdsOnly |
If true, the response only includes an array of object IDs. Otherwise the response is a feature set. The default is false. Note that while there is a limit on the number of features included in the feature set response, there is no limit on the number of object IDs returned in the ID array response. Clients can exploit this to get all the query conforming object IDs by specifying returnIdsOnly is true and subsequently requesting feature sets for subsets of object IDs. Values: true | false |
returnCountOnly |
This option was added at 10.0 SP1. If true, the response only includes the count (number of features/records) that would be returned by a query. Otherwise the response is a feature set. The default is false. This option supersedes the returnIdsOnly parameter. Values: true | false |
returnExtentOnly | This option was added at 10.4. If true, the response only includes the extent of the features that would be returned by the query. If returnCountOnly is true, the response will return both the count and the extent. The default is false. This parameter applies only if the supportsReturningQueryExtent property of the layer is true. Values: true | false |
orderByFields |
This option was added at 10.1. This parameter specifies one or more field names or expressions that the features or records need to be ordered by. Use ASC or DESC for ascending or descending order, respectively. This parameter is supported on only those layers and tables that have the supportsAdvancedQueries property set to true. When used with outStatistics, only field names specified in outStatisticFieldName or groupByFieldsForStatistics are allowed. orderByFields defaults to ASC (ascending order) if <ORDER> is unspecified. ![]() At 10.4, expressions are allowed in addition to field name. When StandardizedQueries is enabled, only expressions that conform to the specifications are allowed. When StandardizedQueries is disabled, you can pass in any expression that the underlying database allows. Syntax
Example
|
outStatistics |
This option was added at 10.1. This parameter provides definitions for one or more field-based statistics to be calculated. This parameter is only supported on layers and tables that have the supportsStatistics property set to true. When using outStatistics, the following parameters are supported:
![]() If outStatisticFieldName is empty or missing, the map server will assign a field name to the returned statistic field. A valid field name can only contain alphanumeric characters and an underscore. Values: An array of statistic definitions. A statistic definition specifies the type of statistic, the field on which it is to be calculated, and the resulting output field name. Syntax
Example
|
groupByFieldsForStatistics |
Added at 10.1. This parameter specifies one or more field names using the values that need to be grouped for calculating the statistics. At 10.4, expressions are allowed in addition to field name. When StandardizedQueries is enabled, only expressions that conform to the specifications are allowed. When StandardizedQueries is disabled, you can pass in any expression that the underlying database allows.
![]() This parameter is only valid when the outStatistics parameter is used. Syntax
Example
|
returnZ |
Added at 10.1. If true, the z-values will be included in the results if the features have z-values. Otherwise z-values are not returned. The default is false.
![]() This parameter only applies if returnGeometry is true. |
returnM |
Added at 10.1. If true, m-values will be included in the results if the features have m-values. Otherwise, m-values are not returned. The default is false.
![]() This parameter only applies if returnGeometry is true. |
gdbVersion |
Added at 10.1. GeoDatabase version to query. This parameter applies only if the hasVersionedData property of the service and the isDataVersioned property of the layers queried are true. If this is not specified, the query will apply to the published map's version. Syntax
Example
|
returnDistinctValues |
Added at 10.1 SP1. If true, returns distinct values based on the fields specified in outFields. This parameter applies only if the supportsAdvancedQueries property of the layer is true. ![]() This parameter cannot be used when returnGeometry is true. Syntax
Example
|
returnTrueCurves |
Added at 10.3. If true, returns true curves in output geometries; otherwise, curves are converted to densified polylines or polygons. Values: true | false |
resultOffset |
Added at 10.3. This option can be used for fetching query results by skipping the specified number of records and starts from the next record (for example, resultOffset + 1th). The Default is 0. This parameter only applies if supportsPagination is true. You can use this option to fetch records that are beyond maxRecordCount. For example, if maxRecordCount is 1,000, you can get the next 100 records by setting resultOffset=1000 and resultRecordCount = 100; query results can return the results in the range of 1,001 to 1,100. |
resultRecordCountsqlFormat |
Added at 10.3. This option can be used for fetching query results up to the resultRecordCount specified. When resultOffset is specified but this parameter is not, the map service defaults it to maxRecordCount. The maximum value for this parameter is the value of the layer's maxRecordCount property. This parameter only applies if supportsPagination is true. Example
|
sqlFormat | The sqlFormat parameter can be either standard SQL-92 standard or it can use the native SQL of the underlying data store native. The default is none, which means the sqlFormat depends on the useStandardizedQuery parameter. The native format is supported when useStandardizedQuery is false. For more information on formatting, see the SQL format section below. ![]() You must check for the supportsSqlFormat layer property before using this parameter. Values: none | standard | native |
datumTransformation | This option was added at 10.5. Use this parameter to apply a datum transformation while projecting geometries in the results when outSR is different than the layer's spatial reference. ![]() While specifying transformation, consider which datum transformation is the most applicable to project the layer (not the map service) to the outSR. The sourceSpatialReference property in the layer resource reports which spatial reference features are stored in the source dataset. For a list of valid datum transformation ID values and well-known text strings, see Using spatial references. For more information on datum transformations, see the transformation parameter in the Project operation. Syntax
Examples
|
rangeValues | This option was added at 10.5. It allows you to filter features from the layer that are within the specified range instant or extent. ![]() Check rangeInfos at the layer resources for the available ranges. Syntax
Example
|
quantizationParameters | This option was added at 10.6.1. This is used to project the geometry onto a virtual grid, likely representing pixels on the screen. For JSON property descriptions and examples, see the Quantization parameters JSON properties section below. ![]() This parameter only applies if supportsCoordinatesQuantization is true. |
parameterValues | This option was added at 10.5. It allows you to filter the features layers by specifying values to an array of preauthored parameterized filters for those layers. When a value is not specified for any parameter in a request, the default value, which is assigned during authoring time, is used instead. When a parameterInfo allows multiple values, you must pass them in an array. ![]() Check parameterInfos at the layer resources for the available parameterized filters, their default values, and expected data type. Syntax
Example
|
historicMoment | This option was added at 10.6.1. This specifies the historic moment to query. This parameter applies only if the layer is archiving enabled and the supportsQueryWithHistoricMoment property is set to true. This property is provided in the layer resource. If historicMoment is not specified, the query will apply to the current features. Syntax
Example
|
lodType (Binning LOD Type ) | Added at 10.9. This specifies the lodType. Check layer resources to find the lodType supported by a layer. Values: esriGeometryPoint | esriGeometryMultipoint | esriGeometryPolyline | esriGeometryPolygon | esriGeometryEnvelope |
lod (Binning LOD Level) | Added at 10.9. This specifies the lod level. Check layer resources for available levels. |
lodSR (Binning LOD Spatial Reference) | Added at 10.9. This specifies the lod level. Check layer resources for available LOD spatial reference. |
f |
The response format. The default response format is html. Protocol buffer (pbf) format is only supported when the supportedQueryFormat property on the layer includes pbf.
![]() kmz will always return z-values. Values: html | json | geojson | kmz | pbf (default, when returnIdsOnly=false and returnCountOnly=false) Values: html | json (when outStatistics is specified) Values: html | json | geojson | pbf (when either returnIdsOnly=true or returnCountOnly=true is specified) ![]() The output format f=geojson is not supported if returnM is true. |
Quantization parameters JSON properties
The following table outlines the JSON properties for the quantizationParameters parameter:
Property | Details |
---|---|
extent | An extent defining the quantization grid bounds. Its SpatialReference matches the input geometry spatial reference if one is specified for the query. Otherwise, the extent will be in the layer's spatial reference. |
mode | Geometry coordinates are optimized for viewing and displaying of data. Value: view |
originPosition | Integer coordinates will be returned relative to the origin position defined by this property value. ![]() Default is upperLeft origin position. Values: upperLeft | lowerLeft |
tolerance | The tolerance is the size of one pixel in the outSpatialReference units. This number is used to convert the coordinates to integers by building a grid with resolution matching the tolerance. Each coordinate is then snapped to one pixel on the grid. Consecutive coordinates snapped to the same pixel are removed to reduce the overall response size. The units of tolerance are defined by outSpatialReference. If the outSpatialReference is not specified, tolerance is assumed to be in the unit of the spatial reference of the layer. If the tolerance is not specified, the maxAllowableOffset is used. ![]() If the tolerance and maxAllowableOffset are not specified, a default 10,000 by 10,000 grid is used. |
Example one
The following example demonstrates possible values for the quantizationParameters parameter:
quantizationParameters={"mode":"view","originPosition":"upperLeft","tolerance":1.0583354500042335,"extent":{"type":"extent","xmin":-18341377.47954369,"ymin":2979920.6113554947,"xmax":-7546517.393554582,"ymax":11203512.89298139,"spatialReference":{"wkid":102100,"latestWkid":3857}}}
The following is a sample URL that reflects the JSON object above:
https://machine.domain.com/arcgis/rest/services/USAShapeFoldersDec5/FeatureServer/2/query?f=html&where=1=1&returnGeometry=true&spatialRel=esriSpatialRelIntersects&outFields=*&outSR=102100&resultOffset=0&resultRecordCount=2000&quantizationParameters={"mode":"view","originPosition":"upperLeft","tolerance":1.0583354500042335,"extent":{"type":"extent","xmin":-19838806.04126036,"ymin":2146082.189218864,"xmax":-7455049.448307296,"ymax":11542768.51809405,"spatialReference":{"wkid":102100,"latestWkid":3857}}}
Example two
The following example demonstrates possible values for the quantizationParameters parameter:
{"mode":"view","originPosition":"lowerLeft","tolerance":1.0583354500042335,"extent":{"type":"extent","xmin":-18341377.47954369,"ymin":2979920.6113554947,"xmax":-7546517.393554582,"ymax":11203512.89298139,"spatialReference":{"wkid":102100,"latestWkid":3857}}}
The following is a sample URL that reflects the JSON object above:
https://machine.domain.com/arcgis/rest/services/USAShapeFoldersDec5/FeatureServer/1/query?where=1=1&objectIds=&time=&geometry=&geometryType=esriGeometryEnvelope&inSR=&spatialRel=esriSpatialRelIntersects&distance=&units=esriSRUnit_Meter&outFields=*&returnGeometry=true&maxAllowableOffset=1.0583354500042335&geometryPrecision=&outSR=102100&returnIdsOnly=false&returnCountOnly=false&returnExtentOnly=false&orderByFields=&groupByFieldsForStatistics=&outStatistics=&resultOffset=0&resultRecordCount=2000&returnZ=false&returnM=false&quantizationParameters={"mode":"view","originPosition":"lowerLeft","tolerance":1.0583354500042335,"extent":{"type":"extent","xmin":-18341377.47954369,"ymin":2979920.6113554947,"xmax":-7546517.393554582,"ymax":11203512.89298139,"spatialReference":{"wkid":102100,"latestWkid":3857}}}&f=html&token=
Percentile statistic type
The percentile statisticType is supported if the supportsPercentileStatistics layer property (in advancedQueryCapabilities) is true. The percentile indicates the value below or above which a given percentage of values in a group of data values falls. For example, the ninetieth percentile (value 0.9) is the value below which 90 percent of the data values may be found. For percentile statistics, there are two statisticTypes, PERCENTILE_DISC (discrete) and PERCENTILE_CONT (continuous). Discrete returns a data value from within that dataset, while continuous is an interpolated value.
The orderBy statistic parameter can also be used to calculate the percentile. For example, in a set of 10 values from 1 to 10, the percentile value for 0.9 with orderBy set as ascending (ASC) is 9, while the percentile for value 0.9 with orderBy set as descending (DESC) is 2. The default is ASC.
Syntax
[
{
"statisticType": "<PERCENTILE_CONT | PERCENTILE_DISC>",
"statisticParameters": {
"value": percentile_value,
"orderBy": "<ASC | DESC>"
},
"onStatisticField": "Field1",
"outStatisticFieldName": "Out_Field_Name1"
},
{
"statisticType": "<PERCENTILE_CONT | PERCENTILE_DISC>",
"statisticParameters": {
"value": percentile_value,
"orderBy": "<ASC | DESC>"
},
"onStatisticField": "Field2",
"outStatisticFieldName": "Out_Field_Name2"
}
]
Example
[
{
"statisticType": "PERCENTILE_CONT",
"statisticParameters": {
"value": 0.9
},
"onStatisticField": "NEAR_DIST",
"outStatisticFieldName": "pop90_cont"
},
{
"statisticType": "PERCENTILE_DISC",
"statisticParameters": {
"value": 0.9,
"orderBy": "DESC"
},
"onStatisticField": "population",
"outStatisticFieldName": "pop90_desc"
}
]
Example usage
The following examples demonstrate various ways to create a sample query request URL for different use cases:
- Example one—Query using the text parameter on the states layer of ESRI_StateCityHighway_USA.
- Example two—Query using a WHERE statement on the same layer.
- Example three—Query strings are case sensitive. In this example, UPPER is used to make the query case insensitive.
- Example four—Query the same states layer using geometry (envelope).
- Example five—Query the states layer by both geometry (envelope) and a WHERE statement.
- Example six—Query the states layer by a WHERE statement, specifying a list of fields to return, and requesting no geometry in the results.
- Example seven—Query the states layer by text parameter and requesting the geometry with the well-known ID of 102113 (Web Mercator).
- Example eight—Query a table using a WHERE clause and return object IDs only.
- Example nine—Use groupByFieldsForStatistics and outStatistics.
- Example ten—Page through a query result using resultOffset and resultRecordCount.
Example one
The following example demonstrates a query using the text parameter on the states layer of ESRI_StateCityHighway_USA:
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?text=Texas&f=pjson
Example two
The following example demonstrates a query using a WHERE statement on the same layer. The output is JSON format.
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?where=STATE_NAME='Florida'&f=json
Example three
The following example demonstrates a query with strings that are case sensitive. In this example, UPPER is used to make the query case insensitive.
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?where=UPPER(STATE_NAME)=UPPER('colorado')&f=pjson
Example four
The following example demonstrates querying the same states layer using geometry (envelope):
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?geometry=-125.4,35.2,-118.7,43.8&geometryType=esriGeometryEnvelope&f=pjson
Example five
The following example demonstrates querying the states layer by both geometry (envelope) and a WHERE statement:
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?geometry=-125.4,35.2,-118.7,43.8&geometryType=esriGeometryEnvelope&where=POP1999>5000000&f=pjson
Example six
The following example demonstrates querying the states layer by a WHERE statement, specifying a list of fields to return, and requesting no geometry in the results:
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?where=POP1999>15000000&returnGeometry=false&outFields=STATE_NAME,MALES,FEMALES,POP1999&f=pjson
Example seven
The following example demonstrates querying the states layer by text parameter and requesting the geometry with the well-known ID of 102113 (Web Mercator):
https://sampleserver1.arcgisonline.com/ArcGIS/rest/services/Specialty/ESRI_StateCityHighway_USA/MapServer/1/query?text=New+York&outSR=102113&f=pjson
Example eight
The following example demonstrates querying a table using a WHERE clause and return object IDs only:
https://sampleserver3.arcgisonline.com/ArcGIS/rest/services/SanFrancisco/311Incidents/MapServer/1/query?objectIds=&where=agree_with_incident+%3D+1&returnGeometry=true&returnIdsOnly=true&f=html
Example nine
The following example demonstrates using groupByFieldsForStatistics and outStatistics:
https://sampleserver6.arcgisonline.com/arcgis/rest/services/Census/MapServer/3/query?where=&text=&objectIds=&time=&geometry=&geometryType=esriGeometryEnvelope&inSR=&spatialRel=esriSpatialRelIntersects&relationParam=&outFields=&returnGeometry=true&maxAllowableOffset=&outSR=&returnIdsOnly=false&returnCountOnly=false&orderByFields=&groupByFieldsForStatistics=sub_region&outStatistics=[{"statisticType":"sum","onStatisticField":"pop2007","outStatisticFieldName":"Population_2007"},{"statisticType":"avg","onStatisticField":"AVE_FAM_SZ","outStatisticFieldName":"Average_Family_Size"}]&returnZ=false&returnM=false&gdbVersion=&f=pjson
Example ten
The following example demonstrates paging through a query result using resultOffset and resultRecordCount, and requesting to skip the first 5 records and return the next 10 counties in California in order by population:
https://machine.domain.com/arcgis/rest/services/USA/MapServer/3/query?where=STATE_NAME='California'&outFields=Name,Population&returnGeometry=false&resultOffset=5&resultRecordCount=10&orderByFields=Population&f=pjson
JSON Response syntax
The examples below demonstrate various JSON response syntax that can be returned for the query operation.
Example one
The following example syntax is returned when returnIdsOnly and returnCountOnly are false:
{
"displayFieldName": "<displayFieldName>",
"fieldAliases": { //fieldAliases deprecated at 10
"<fieldName1>": "<fieldAlias1>",
"<fieldName2>": "<fieldAlias2>"
},
"fields": [
{
"name": "<fieldName1>",
"type": "<fieldType1>",
"alias": "<fieldAlias1>",
"length": "<length1>"
},
{
"name": "<fieldName2>",
"type": "<fieldType2>",
"alias": "<fieldAlias2>",
"length": "<length2>"
}
],
"geometryType": "<geometryType>", //for layers only
"spatialReference": <spatialReference>, //for layers only
"hasZ": <true|false>, //added in 10.1
"hasM": <true|false>, //added in 10.1
"features": [ //features may include geometry for layers only
<feature1>,
<feature2>
]
}
Example two
The following example syntax is returned when returnIdsOnly is false:
{
"objectIdFieldName": "<objectIdFieldName>",
"objectIds": [
<objectId1>,
<objectId2>
]
}
Example three
The following example syntax is returned when returnCountOnly is true:
{
"count": <count>
}
Example four
The following example syntax is returned when groupByFieldsForStatistics and outStatistics are specified:
{
"displayFieldName": "",
"fieldAliases": {
"alias1": "fieldAlias1",
"alias2": "fieldAlias2"
},
"fields": [
{
"name": "fieldName1",
"type": "fieldType1",
"alias": "fieldAlias1",
"length": fieldLength1
},
{
"name": "fieldName2",
"type": "fieldType2",
"alias": "fieldAlias2",
"length": fieldLength2
}
],
"features": [<feature1>, <feature2>] //Feature object without geometry
}
JSON Response examples
The examples below demonstrate various JSON responses that can be returned for the query operation.
Example one
The following example response is returned when returnIdsOnly and returnCountOnly are false:
{
"displayFieldName": "AREANAME",
"fieldAliases": {
"ST": "ST",
"POP2000": "Population - 2000",
"AREANAME": "City Name"
},
"fields": [
{
"name": "ST",
"alias": "ST",
"type": "esriFieldTypeString",
"length": 2
},
{
"name": "POP2000",
"alias": "Population - 2000",
"type": "esriFieldTypeInteger"
},
{
"name": "AREANAME",
"alias": "City Name",
"type": "esriFieldTypeString",
"length": 255
}
],
"geometryType": "esriGeometryPoint",
"spatialReference": {
"wkid": 4326
},
"features": [
{
"attributes": {
"ST": "CA",
"POP2000": 3694820,
"AREANAME": "Los Angeles"
},
"geometry": {
"x": -118.37,
"y": 34.086
}
},
{
"attributes": {
"ST": "CA",
"POP2000": 461522,
"AREANAME": "Long Beach"
},
"geometry": {
"x": -118.15,
"y" : 33.80
}
}
]
}
Example two
The following example response is returned when returnIdsOnly is true:
{
"objectIdFieldName": "objectid",
"objectIds": [
1,
2,
3,
4,
5,
7
]
}
Example three
The following example response is returned when returnCountOnly is true:
{
"count":48
}
Example four
The following example response is returned when groupByFieldsForStatistics and outStatistics are specified:
{
"displayFieldName": "",
"fieldAliases": {
"sub_region": "SUB_REGION",
"Population_2007": "Population_2007",
"Average_Family_Size": "Average_Family_Size"
},
"fields": [
{
"name": "sub_region",
"type": "esriFieldTypeString",
"alias": "SUB_REGION",
"length": 20
},
{
"name": "Population_2007",
"type": "esriFieldTypeDouble",
"alias": "Population_2007"
},
{
"name": "Average_Family_Size",
"type": "esriFieldTypeDouble",
"alias": "Average_Family_Size"
}
],
"features": [
{
"attributes": {
"sub_region": "Pacific",
"Population_2007": 49731702,
"Average_Family_Size": 3.2439999999999998
}
},
{
"attributes": {
"sub_region": "Mountain",
"Population_2007": 21492235,
"Average_Family_Size": 3.165
}
},
{
"attributes": {
"sub_region": "New England",
"Population_2007": 14515009,
"Average_Family_Size": 3.0249999999999999
}
},
{
"attributes": {
"sub_region": "West North Central",
"Population_2007": 20384497,
"Average_Family_Size": 3.044285714285714
}
},
{
"attributes": {
"sub_region": "East North Central",
"Population_2007": 47176974,
"Average_Family_Size": 3.0940000000000003
}
},
{
"attributes": {
"sub_region": "Middle Atlantic",
"Population_2007": 41116339,
"Average_Family_Size": 3.1566666666666663
}
},
{
"attributes": {
"sub_region": "South Atlantic",
"Population_2007": 58943344,
"Average_Family_Size": 3.0333333333333332
}
},
{
"attributes": {
"sub_region": "East South Central",
"Population_2007": 18077309,
"Average_Family_Size": 3.0275000000000003
}
},
{
"attributes": {
"sub_region": "West South Central",
"Population_2007": 34910821,
"Average_Family_Size": 3.1124999999999998
}
}
]
}